B
B-Se
-Series
rie
s
CIRCUIT BREAKER
Carling Technologies’ B-Series hydraulic magnetic circuit breakers are specifically designed for applications
requiring extra insulation and tongue and groove half-shell constructions. The B-Series carries global regulatory
safety approvals for spacing requirements and are ideal for use as general purpose as well as full load amp
applications. Available with various choices of time delays, terminals, actuator styles, with a wide range of
standard colors and imprinting.
1-6 poles; ratings from 0.02 to 50 amps, up to 277VAC or 80VDC; UL recognized, CSA, VDE -0642, TUV,
UL-1500, UL489A Listed
Resources:
Configure a Complete Part
Download CAD & Sales Drawing
Product Highlights:
•ꢀ MeetꢀCSAꢀStandardꢀ22.2ꢀNo.ꢀ100ꢀforꢀthe
ꢀ Generatorꢀ&ꢀWelderꢀmarkets
•ꢀ Extraꢀinsulationꢀandꢀtongueꢀ&ꢀgrooveꢀhalf-shellꢀꢀ
ꢀ constructions
•ꢀ ULꢀRecognizedꢀ-ꢀULꢀStandardꢀ508,ꢀ1077,ꢀ1500
•ꢀ ULꢀListedꢀ-ꢀULꢀStandardꢀ489,ꢀ489A
•ꢀ CSAꢀAccepted
Typical Applications:
•ꢀ PowerꢀSupplies
•ꢀ MedicalꢀEquipment
•ꢀ Generatorsꢀ&ꢀWelders
•ꢀ OfficeꢀEquipment
•ꢀ ControlꢀPanels
•ꢀ Marine
•ꢀ Military
•ꢀ TUVꢀCertified
•ꢀ VDEꢀCertified
Carling Technologies, Inc.
60 Johnson Avenue, Plainville, CT 06062
Email: sales@carlingtech.com
Application Support: team2@carlingtech.com
Phone: 860.793.9281 Fax: 860.793.9231
www.carlingtech.com
|
B-Series Circuit Breaker – General Specifications
2
Electrical
Maximum Voltage
Current Ratings
Mechanical
277VAC 50/60 Hz, 80VDC
Standard current coils: 0.100,
0.250, 0.500, 0.750, 1.00, 2.50,
5.00, 7.50, 10.0, 15.0, 20.0, 25.0,
30.0, 35.0, 40.0 and 50.0 amps.
Other ratings available, see
ordering scheme.
Endurance
10,000 ON-OFF operations @ 6 per
minute; with rated Current and
Voltage.
All B-Series Circuit Breakers will
trip on overload, even when Handle
is forcibly held in the ON position.
The operating Handle moves
positively to the OFF position when
an overload causes the breaker to
trip.
Trip Free
Trip Indication
Standard Voltage Coils DC - 6V, 12V; AC - 120V, other
ratings available, see ordering
scheme.
Auxiliary Switch Rating SPDT; 10.1 AMPS - 250VAC,1.0A
65 VDC or 0.5A 80 VDC, 0.1 Amps
- 125VAC (with gold contacts).
Physical
Number of Poles
1 - 6 poles at 30 Amps or less. 1
and 2 poles at 31 Amps thru 50
Amps.
VDE-1.0 Amp - 125VAC.
Minimum of 100 Megohms at 500
VDC.
Insulation Resistance
Dielectric Strength
Internal Circuit Config. Series, (with or without auxiliary
switch), Shunt and Relay with
UL, CSA-1500 V 50/60 Hz for one
minute between all electrically
isolated terminals. B-Series circuit
breakers comply with the 8mm
spacing and 3750V 50/60 Hz
dielectric requirements from
hazardous voltage to operator
accessible surfaces, between
adjacent poles and from main
circuits to auxiliary circuits per
Publications EN 60950 and VDE
0805.
current or voltage trip coils, Dual
Coil, Switch Only (with or without
auxiliary switch).
Approximately 65 grams/pole.
(Approximately 2.32 ounces/pole.)
Housing- Black; Actuator - See
Ordering Scheme.
Weight
Standard Colors
Environmental
Designed and tested in accordance with requirements of
specification MIL-PRF-55629 & MIL-STD-202 as follows:
Resistance, Impedance Values from Line to Load Terminal
- based on Series Trip Circuit
Breaker.
RESISTANCE PER POLE VALUES
from Line to Load Terminals
(Values Based on Series Trip Circuit Breaker)
Shock
Withstands 100 Gs, 6ms, sawtooth
while carrying rated current per
Method 213, Test Condition “I”.
Instantaneous and ultra-short
curves tested @ 90% of rated
current.
Withstands 0.060” excursion from
10-55 Hz, and 10 Gs 55-500 Hz,
at rated current per Method 204C,
Test Condition A. Instantaneous
and ultrashort curves tested at 90%
of rated current.
CURRENT
(AMPS)
TOLERANCE
(%)
0.10 - 5.0
5.1 - 20.0
20.1 - 50.0
15
25
35
Vibration
Moisture Resistance
Method 106D, i.e., ten 24-hour
cycles @ + 25°C to +65°C, 80-98%
RH.
Salt Spray
Method 101, Condition A (90-95%
RH @ 5% NaCl Solution, 96 hrs).
Method 107D, Condition A (Five
cycles @ -55°C to +25°C to +85°C
to +25°C).
Pulse Tolerance Curves
Thermal Shock
Operating Temperature -40° C to +85° C
*Manufacturer reserves the right to change product specification without prior notice.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
3
B-Series Circuit Breaker – General Specifications
Electrical Tables
Table A: Lists UL Recognized & CSA Certified configurations and performance capabilities as a Component Supplementary Protector.
Notes:
1
2
3
4
Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse (15A minimum) at no more than 4 times the rating of the protector.
Same as note 1, except that backup fuse is limited to 80A maximum.
2 pole protector required (with one pole per power line) for: 250/125 VAC, 125/250 VAC and 208Y/120 VAC Power Systems. 1 pole protector required for : 125 VAC, 1Ø Power System.
Satisfies the requirements of clause 11.2.8.2.5 of CSA STD C22.2 No 100 for the use of supplementary protectors with portable generators.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
4
B-Series Circuit Breaker – General Specifications
Electrical Tables
Table B: Lists UL Recognized, CSA, VDE & TUV Certified configurations & performance capabilities as a Component Supplementary
Protector.
Notes:
1
2
3
General Purpose Ratings for UL/CSA Only.
Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse (15A minimum) at no more than 4 times the rating of the protector.
Same as note 1, except that backup fuse is limited to 80 A maximum.
Table C: Lists UL Recognized, CSA Certified configurations and performance capabilities as Protectors, Supplementary for Marine
Electrical and Fuel Systems (CCN/Guide PEQZ2, File E75596). Ignition Protected per UL 1500. UL Classified Small Craft Electrical Devices,
Marine in accordance with ISO 8846 (CCN/Guide UZMK, File MQ1515) as Marine Supplementary Protectors.
Notes:
1
2
Available with special catalog number only (consult factory).
2 pole protector required (with one pole per power line) for: 250/125 VAC, 125/250 VAC and 208Y/120 VAC Power Systems. 1 pole protector required for : 125 VAC, 1Ø Power System.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
5
B-Series Circuit Breaker – General Specifications
Table D: Lists UL Listed configurations and performance capabilities as Circuit Breakers for use in Communications Equipment (CCN/
Guide DITT, File E189195), under UL489A
Notes:
1
Parallel Pole Construction
Table E: Lists UL Listed (489) configuration and performance capabilities as a Molded Case Circuit Breaker.
B SERIES TABLE E : UL489 LISTED BRANCH CIRCUIT BREAKERS
VOLTAGE
INTERRUPTING
CAPACITY (AMPS)
CURRENT RATING
CIRCUIT
CONFIGURATION
CONSTRUCTION NOTES
MAX. RATING FREQUENCY PHASE
WITHOUT BACKUP
FUSE
FULL LOAD AMPS
1 Pole
120
50 / 60
50 / 60
50 / 60
50 / 60
50 / 60
1
1
1
1
1
0.10 - 30
0.10 - 30
0.10 - 30
0.10 - 30
0.10 - 30
5,000
5,000
5,000
5,000
5,000
SERIES
2 Poles
120 / 240
120 / 240
120
2 or 3 Poles (1 Pole of a 3 Pole Unit is for Neutral Break)
1 Pole
SHUNT TRIP
DUAL COIL
2 Poles
120 / 240
2 or 3 Poles (1 Pole of a 3 Pole Unit is for Neutral Break)
120 / 240
50 / 60
1
0.10 - 30
5,000
Agency Certifications
Component Supplementary
Protector under Class 3215 30,
FIle 047848 0 000 CSA
UL Recognized
UL Standard 1077
CSA Accepted
Component Recognition Program
as Protectors Supplementary
(Guide CCN/QVNU2, File E75596)
Standard C22.2 No. 235
Switches, Industrial Control
(Guide CCN/NRNT2, File E148683)
EN60934, under License No.
R72103448
UL Standard 508
UL Standard 1500
TUV Certified
VDE Certified
Protectors, Supplementary for
Marine Electrical & Fuel Systems
(Guide PEQZ2, File E75596)
Ignition Protection
EN60934, VDE 0642 under File
No. 10537
UL Listed
UL Standard 489
Circuit Breakers, Molded Case,
(Guide DIVQ, File E129899)
Communications Equipment
UL Standard 489A
(Guide CCN/DITT, File E189195)
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
6
B-Series Circuit Breaker - Handle UL Recognized – Ordering Scheme
B A 3 B 0 10 450 1 B 1 C
8
9
10
Mounting/
Barriers
11
Agency
Approval
1
2
3
4
5
6
7
Terminal
Actuator
Color
Series
Actuator
Poles
Circuit
Aux/Alarm
Switch
Frequency
& Delay
Current Rating
1 SERIES
B
7 CURRENT RATING (AMPERES)
CODE AMPERES
020 0.020
025 0.025
030 0.030
035 0.035
040 0.040
045 0.045
050 0.050
055 0.055
060 0.060
065 0.065
070 0.070
075 0.075
080 0.080
085 0.085
090 0.090
095 0.095
210 0.100
215 0.150
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
295 0.950
410 1.000
512 1.250
415 1.500
517 1.750
420 2.000
522 2.250
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611 11.000
711 11.500
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
2 ACTUATOR
A
B
S
T
Handle, one per pole
Handle, one per multipole unit
Mid-Trip Handle, one per pole
Mid-Trip Handle, one per pole & Alarm Switch
3 POLES
1
2
One
Two
3
4
Three
Four
5
6
Five
Six
4 CIRCUIT
8
635 35.000
2
3
3,4
A
B
C
D
E
F
Switch Only (No Coil)
G
H
Relay Trip (Voltage)
Dual Coil with Shunt Trip
Voltage Coil
Dual Coil with Relay Trip
Voltage Coil
8
640 40.000
Series Trip (Current)
Series Trip (Voltage)
Shunt Trip (Current)
Shunt Trip (Voltage)
Relay Trip (Current)
8
645 45.000
8
650 50.000
3
3
3
3,4
K
6
OR VOLTAGE COIL (NORMAL RATED VOLTAGE)
CODE AMPERES
A06
6 DC
A32 32 DC
A48 48 DC
A65 65 DC
J12 12 AC
J18 18 AC
J24 24 AC
J48 48 AC
J65
65 AC
A12 12 DC
A18 18 DC
A24 24 DC
K20 120 AC
L40 240 AC
5
5 AUXILIARY / ALARM SWITCH
J06
6 AC
0
2
4
without Aux Switch
7
S.P.S.T., 0.110 Q.C. Term.
(Gold Contacts)
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
S.P.D.T., 0.110 Q.C. Term.
S.P.D.T., 0.110 Q.C. Term.
(Gold Contacts)
9
8
9
8 TERMINAL
F
Screw M5 with upturned lugs
& 30° bend
10
1
2
3
4
5
6
Push-On 0.250 Tab (Q.C.)
Screw 8-32 with upturned lugs
Screw 8-32 (Bus Type)
Screw 10-32 with upturned lugs
Screw 10-32 (Bus Type)
Screw 8-32 with upturned lugs
& 30° bend
G
H
J
K
L
M
N
P
Q
R
Screw M5 (Bus Type) & 30° bend
Screw M5 (Bus Type)
Screw M5 Back Connect
Screw 10-32 Back Connect
0.250 Q.C./ Solder Lug
M6 Threaded Stud
11
11
6 FREQUENCY & DELAY
2
6
03 DC 50/60Hz, Switch Only
30 DC, 50/60Hz Instantaneous
31 DC, 50/60Hz Ultra Short
32 DC, 50/60Hz Short
12
11
10 DC Instantaneous
11 DC Ultra Short
12 DC Short
7
8
9
Screw 8-32 (Bus Type)
& 30° bend
Screw M4 Back Connect
Printed Circuit Board Terminals
Push-In Stud
34 DC, 50/60Hz Medium
36 DC, 50/60Hz Long
13
16
14 DC Medium
16 DC Long
Screw 10-32 with upturned lugs
& 30° bend
7
7
7
7
7
7
42 50/60Hz Short, High-inrush
Screw M4 with upturned lugs
& 30° bend
6
20 50/60Hz Instantaneous
44 50/60Hz Medium, High-inrush
Screw 10-32 (Bus Type)
& 30° bend
Screw M5 with upturned lugs
Screw M4 with upturned lugs
Screw M4 (Bus Type)
15
21 50/60Hz Ultra Short
22 50/60Hz Short
24 50/60Hz Medium
26 50/60Hz Long
46 50/60Hz Long, High-inrush
S
Push-On 0.110 Tab (Q.C.)
& 30° bend
52 DC, Short, High-inrush
B
C
E
54 DC, Medium, High-inrush
T
Y
Screw M4 (Bus Type) & 30° bend
Screw 8-32 Back Connect
11
56 DC, Long, High-inrush
Notes:
1 Actuator Code:
9 ACTUATOR COLOR & LEGEND
Actuator Color
White
I-O
A
C
F
H
K
M
P
ON-OFF
Dual
Legend Color
Black
A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units.
B: Handle location as viewed from front of breaker:
B
D
G
J
1
2
3
4
5
6
7
8
Black
White
2 pole - left pole
4 pole - two handles at center poles
6 pole - four handles at center poles
3 pole - center pole
5 pole - three handles at center poles
Red
White
Green
Blue
Yellow
Gray
White
L
White
S: Handle moves to mid-position only upon electrical trip of the breaker. Available with circuit
codes B, C, D, E, F, G, H and K.
T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the
breaker. Available with circuit codes B & C.
N
Q
S
Black
Black
Orange
R
Black
2
Switch Only circuits, rated up to 50 amps and 6 poles, and only available with VDE
Certification when tied to a protected pole (Circuit Code B, C, D or H.), For .02 to 30 amps,
select Current Code 630. For 35 - 50 amps, select Current Code 650.
Available with Terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum.
Consult factory for available Dual Coil options, as special catalog number is required. With
Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils require
30VA minimum power to trip and are rated for intermittent duty only.
Auxiliary Switch breakers with Series Trip and Switch Only circuits. On multi-pole breakers,
one auxiliary switch is supplied, mounted in the extreme right pole.
Separate pole type voltage coils not rated for continuous duty. Available only with delay
codes 10 and 20.
Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized and
CSAAccepted to 50 amps.
VDE Certification available with single pole breakers with DC Delay only. UL Recognition
and CSAAccepted available in one and two pole breakers.
Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps
are only available with Terminal Codes 5, 9, G, H, J, K, M and Q.
10 MOUNTING / BARRIERS
MOUNTING STYLE
BARRIERS
3
4
Threaded Insert, 2 per pole
1
6-32 x 0.195 inches
no
A
2
6-32 x 0.195 inches (multi-pole units only)
ISO M3 x 5mm
yes
no
5
6
7
8
9
B
ISO M3 x 5mm
yes
Rectangular Adapter Plate with mounting centers of 2.062
inches [52.37mm] and Threaded insert, 2 per pole
14
14
14
14
3
6-32 x 0.225 inches
no
C
4
6-32 X 0.225 inches (multi-pole units only)
ISO M3 x 6.5mm
yes
no
D
ISO M3 x 6.5mm
yes
Front panel Snap-In, 0.75” [19.05mm] wide bezel
without Handleguard
5
6
no
yes
without Handleguard (multipole only)
Front panel Snap-In, 0.96” wide bezel
without Handleguard, 1-pole 0.96” wide;
multipole units have .105” bezel overhang on all sides
without Handleguard, 1-pole 0.96” wide;
(multipole only) .105” bezel overhang on all sides
10 VDE Certification up to 25 amps and UL Recognition and CSAAcceptance up to 30 amps,
but not recommended over 20 amps.
7
8
no
11 Terminal Codes 3, 5 E and H (Bus Type) with VDE, are supplied with Lock Washers, and
Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers.
These breakers are only VDE Certified when the washers are used.
12 VDE Cert. available up to 12 amps. UL Rec. & CSAAcceptance available up to 30 amps.
13 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30
amps with VDE Certification and 50 amps with UL Recognition and CSAAcceptance, with
Circuit Codes A, B and C. Two pole breakers with Terminal Code P (Printed Circuit Board)
are available up to 40 amps with UL Recognition and CSAAcceptance with Circuit Codes
A, B and C.
yes
11 AGENCY APPROVAL
C
D
E
I
UL Recognized & CSA Accepted
VDE Certified, UL Recognized & CSA Accepted
TUV Certified, UL Recognized & CSA Accepted
UL Recognized STD 1077, UL Recognized 1500 (ignition protected),
& CSA Accepted
14 Available with Actuator Codes A, S and T.
15 Available with voltage coils only.
16 Terminal Code Q not available with VDE approvals.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
7
B-Series Circuit Breaker - Handle UL489A – Ordering Scheme
B A 1 B 0 14 450 1 B 1 M T
8
9
10
Mounting/
Barriers
11
12
1
2
3
4
5
6
7
Terminal
Actuator
Color
Max. Appl. Agency
Rating
Series
Actuator
Poles
Circuit
Aux/Alarm
Switch
Frequency
& Delay
Current Rating
Approval
1 SERIES
9 ACTUATOR COLOR & LEGEND
B
Actuator Color
White
ON-OFF
Dual
Legend Color
Black
B
D
G
J
1
2
3
4
5
6
7
8
Black
White
1
2 ACTUATOR
Red
White
A
B
S
T
Handle, one per pole
Green
Blue
Yellow
Gray
White
Handle, one per multipole unit
Mid-Trip Handle, one per pole
L
White
N
Q
S
Black
Mid-Trip Handle, one per pole & Alarm Switch
Black
Orange
Black
2
3 POLES
1
2
One
Two
3
4
Three
Four
10 MOUNTING / BARRIERS
MOUNTING STYLE
BARRIERS
Threaded Insert, 2 per pole
1
6-32 x 0.195 inches
no
4 CIRCUIT
A
2
6-32 x 0.195 inches (multi-pole units only)
ISO M3 x 5mm
yes
no
B
Series Trip (Current)
B
ISO M3 x 5mm
yes
Rectangular Adapter Plate with mounting centers of 2.062
inches [52.37mm] and Threaded insert, 2 per pole
2
5 AUXILIARY / ALARM SWITCH
0
2
3
7
without Aux Switch
8
9
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
3
6-32 x 0.225 inches
no
S.P.D.T., 0.110 Q.C. Term.
S.P.D.T., 0.110 Solder Lug
S.P.S.T., 0.110 Q.C. Term.
(Gold Contacts)
C
4
6-32 X 0.225 inches (multi-pole units only)
ISO M3 x 6.5mm
yes
no
D
ISO M3 x 6.5mm
yes
Front panel Snap-In, 0.75” [19.05mm] wide bezel
without Handleguard
5
6
no
yes
without Handleguard (multipole only)
Front panel Snap-In, 0.96” wide bezel
without Handleguard, 1-pole 0.96” wide;
multipole units have .105” bezel overhang on all sides
without Handleguard, 1-pole 0.96” wide;
(multipole only) .105” bezel overhang on all sides
4
6 FREQUENCY & DELAY
7
8
no
11
12
14
16
DC Ultra Short
DC Short
52
54
56
DC, Short, High-inrush
DC, Medium, High-inrush
DC, Long, High-inrush
yes
DC Medium
DC Long
11 MAXIMUM APPLICATION RATING
80 DC
7 CURRENT RATING (AMPERES)
M
CODE AMPERES
210 0.100
215 0.150
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
295 0.950
410 1.000
512 1.250
415 1.500
517 1.750
420 2.000
522 2.250
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611 11.000
711 11.500
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
12 AGENCY APPROVAL
T
K
J
UL489A Listed
UL489A Listed, VDE Certified
UL489A Listed, TUV Certified
Notes:
1
Actuator Code:
A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units.
S: Handle moves to mid-position only upon electrical trip of the breaker.
T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the
breaker.
3
635 35.000
3
640 40.000
3
645 45.000
2
3
On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole.
VDE Certification available with single pole breakers only. UL489A Listing available with
one and two pole breakers.
Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps
are only available with Terminal Codes 5, 9, G, H, J, K, M and Q.
3
650 50.000
4
5
6
4
8 TERMINAL
5
Terminal Code 1 (Push-On) available up to 25 amps with TUV or VDE Certification and
30 amps with UL489A Listing, but is not recommended over 20 amps.
Terminal Codes 3, 5 and H (Bus Type) with TUV or VDE, are supplied with Lock Washers,
and Terminal Code M (M6 Threaded Stud) with TUV or VDE is supplied with Lock and
Flat Washers. These breakers are only TUV or VDE Certified when the washers are used.
Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30
amps with VDE Certification and 50 amps with UL489A Listing.
1
2
3
4
5
6
Push-On 0.250 Tab (Q.C.)
Screw 8-32 with upturned lugs
Screw 8-32 (Bus Type)
Screw 10-32 with upturned lugs
Screw 10-32 (Bus Type)
Screw 8-32 with upturned lugs
& 30° bend
Screw 8-32 (Bus Type)
& 30° bend
Screw 10-32 with upturned lugs
& 30° bend
B
F
Screw M5 with upturned lugs
Screw M5 with upturned lugs
& 30° bend
6
6
G
H
J
K
M
N
P
Q
Y
Screw M5 (Bus Type) & 30° bend
Screw M5 (Bus Type)
7
8
Screw M5 Back Connect
Screw 10-32 Back Connect
M6 Threaded Stud
Terminal Code Q not available with VDE approvals.
6
7
8
9
Screw M4 Back Connect
Printed Circuit Board Terminals
Push-In Stud
7
8
Screw 10-32 (Bus Type)
& 30° bend
Screw 8-32 Back Connect
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
8
B-Series Circuit Breaker - Handle UL489 Listed – Ordering Scheme
B A 1 B 0 24 450 1 B A K G
8
9
10
Mounting/
Barriers
11
12
1
2
3
4
5
6
7
Terminal
Actuator
Color
Max. Appl. Agency
Rating
Series
Actuator
Poles
Circuit
Aux/Alarm
Switch
Frequency
& Delay
Current Rating
Approval
6
9 ACTUATOR COLOR & LEGEND
1 SERIES
Actuator Color
White
ON-OFF
Dual
Legend Color
Black
B
B
D
G
J
1
2
3
4
5
6
7
8
Black
White
1
2 ACTUATOR
Red
White
A
B
S
T
Handle, one per pole
Green
Blue
Yellow
Gray
White
Handle, one per multipole unit
Mid-Trip Handle, one per pole
L
White
N
Q
S
Black
Mid-Trip Handle, one per pole & Alarm Switch
Black
Orange
Black
2
3 POLES
One
3
1
2
Two
3
Three
10 MOUNTING / BARRIERS
MOUNTING STYLE
BARRIERS
Threaded Insert, 2 per pole
4 CIRCUIT
Series Trip (Current)
A
B
6-32 x 0.195 inches (multi-pole units only)
yes
yes
B
ISO M3 x 5mm
Rectangular Adapter Plate with mounting centers of 2.062
7
inches [52.37mm] and Threaded insert, 2 per pole
4
5 AUXILIARY / ALARM SWITCH
C
D
6-32 X 0.225 inches (multi-pole units only)
ISO M3 x 6.5mm
yes
yes
0
2
3
without Aux Switch
8
9
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
S.P.D.T., 0.110 Q.C. Term.
S.P.D.T., 0.110 Solder Lug
Front panel Snap-In, 0.75” [19.05mm] wide bezel
without Handleguard (multipole only)
Front panel Snap-In, 0.96” wide bezel
without Handleguard, 1-pole 0.96” wide;
(multipole only) .105” bezel overhang on all sides
6
8
yes
yes
6 FREQUENCY & DELAY
21
22
24
26
AC Ultra Short
AC Short
AC Medium
AC Long
42
44
46
AC, Short, High-inrush
AC, Medium, High-inrush
AC, Long, High-inrush
11 MAXIMUM APPLICATION RATING
8
C
K
120/240VAC
120VAC
7 CURRENT RATING (AMPERES)
CODE AMPERES
12 AGENCY APPROVAL
210 0.100
215 0.150
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
295 0.950
410 1.000
512 1.250
415 1.500
517 1.750
420 2.000
522 2.250
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611 11.000
711 11.500
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
G
3
UL489 Listed
UL489 Listed, TUV Certified
Notes:
1
Actuator Code:
A: Handle tie pin spacer(s) and retainers provided un-assembled with multi-pole units.
B: Handle location as viewed from front of breaker:
2 pole - left pole
3 pole - center pole
S: Handle moves to mid-position only upon electrical trip of the breaker. Available with
circuit codes B, C, D, E, F, G, H and K.
T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the
breaker. Available with circuit codes B & C.
2
3
4
All poles must be same polarity.
3 pole units available only when 1 of 3 poles is neutral.
Auxiliary/Alarm Switch circuit must be same polarity as the main circuit. On multi-pole
breakers, one auxiliary switch is supplied, mounted in the extreme right pole.
Screw Terminals are recommended on ratings greater than 20 amps.
Standard actuator colors are black and white.
5
6
7
4
8 TERMINAL
A
Load Terminal #8 Screw with QC
Combination (Special Catalog #)
Screw M5 with upturned lugs
Screw M5 with upturned lugs
& 30° bend
1
2
3
4
5
6
Push-On 0.250 Tab (Q.C.)
Screw 8-32 with upturned lugs
Screw 8-32 (Bus Type)
Screw 10-32 with upturned lugs
Screw 10-32 (Bus Type)
Screw 8-32 with upturned lugs
& 30° bend
Adapter plate with mounting centers of 2.082 inches. Available with Actuator
Codes A, S and T.
Voltage Rating available with 2 and 3-pole breakers only.
Barriers supplied on multi-pole units only.
B
F
8
9
G
H
J
K
M
N
Q
Y
Screw M5 (Bus Type) & 30° bend
Screw M5 (Bus Type)
Screw M5 Back Connect
Screw 10-32 Back Connect
M6 Threaded Stud
7
8
9
Screw 8-32 (Bus Type)
& 30° bend
Screw 10-32 with upturned lugs
& 30° bend
Screw 10-32 (Bus Type)
& 30° bend
Screw M4 Back Connect
Push-In Stud
Screw 8-32 Back Connect
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
9
B-Series Circuit Breaker - Handle – Circuit & Terminal Diagrams
Circuit & Terminal Diagrams: in. [mm]
CIRCUIT SCHEMATIC
CIRCUIT SCHEMATIC
ANSI IEC
ANSI
IEC
SWITCH ONLY (NO COIL)
SERIES TRIP
SERIES TRIP
(2 TERM'S.)
LINE
(NETZ)
LINE
LINE (3)
(NETZ)
LINE
MAIN TERM'S.
(SEE TABLE A)
A
O
B
C
O
I >
LOAD
(LAST)
LOAD
1.730 [43.94]
.520 [13.21]
LOAD
LOAD (LAST)
SERIES TRIP WITH
AUXILIARY / ALARM SWITCH
SWITCH ONLY (NO COIL)
WITH AUXILIARY SWITCH
LINE
LINE (NETZ) (3)
STD. AUX. SWITCH
STD. AUX. SWITCH
SERIES TRIP
W AUX SWITCH
(5 TERM'S.)
LINE (NETZ)
LINE
C
C
C
C
C
NO
NC
NO
NO
A
2
3
4
B
C
2
3
4
NO
NO
I >
NC
ALARM SWITCH
LOAD
NC
NC
NC
ALARM SWITCH
AUX. SWITCH
TERM'S.
LOAD (LAST)
LOAD
LOAD (LAST)
SHUNT TRIP
LINE (NETZ)
DUAL COIL; SERIES TRIP CURRENT COIL,
SHUNT TRIP VOLTAGE COIL
LINE
(3)
LINE (NETZ)
LINE
SHUNT TRIP
(3 TERM'S.)
SHUNT
(NEBENSCHLUSS)
D
E
0
H
0
SHUNT
VOLTAGE
COIL
I >
U >
I >
LOAD
VOLTAGE
COIL
.390 [9.91]
LOAD
LINE
LOAD (LAST)
RELAY TRIP
LOAD
(LAST)
DUAL COIL; SERIES TRIP CURRENT COIL,
RELAY TRIP VOLTAGE COIL
RELAY
(RELAIS)
LINE (3)
(NETZ)
LINE
LINE
(NETZ)
VOLTAGE
COIL
1
4
1
.780 [19.81]
RELAY TRIP
(4 TERM'S.)
1
3
1
1
2
2
3
2
2
3
LOAD
F
G
0
K
0
RELAY
3
VOLTAGE
COIL
I >
4
LOAD
(LAST)
U >
I >
4
3
VOLTAGE
COIL
2
4
4
RELAY
LOAD
(RELAIS)
(LAST)
RELAY
.390 [9.91]
LOAD
HANDLE POSITION VS. AUX/ALARM SWITCH MODE
STANDARD C/B
MID TRIP C/B
MID TRIP C/B
CIRCUIT
BREAKER
MODE
HANDLE POSITION
AUX. SWITCH MODE
HANDLE POSITION
30°
ALARM SWITCH MODE
HANDLE POSITION
30°
AUX. SWITCH MODE
(w/o ALARM SWITCH)
30°
OFF
NC
NC
NC
NO
NO
NO
C
C
C
NC
NC
NC
NO
NO
NO
C
C
C
NC
NC
NC
NO
NO
NO
C
C
C
ON
3
30°
30°
90
30°
90
MID
TRIP
MID
TRIP
ELECTRICAL
TRIP
Notes:
1
2
3
All dimensions are in inches [millimeters].
Tolerance ±.020 [.51] unless otherwise specified.
Alarm Switch available with .110 x .020 Q.C. & Solder Lug Terminals Only.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
10
B-Series Circuit Breaker - Handle – Circuit & Terminal Diagrams
Circuit & Terminal Diagrams: in. [mm]
1.000 [25.40]
.392 [9.97]
CENTERLINE OF PUSH-IN
STUD CONTACT AREA
TERMINAL DIMENSIONAL DETAIL & RATING
.205 [5.21]
.360[9.14]
.392[9.96]
.392[9.96]
.344[8.74]
.750[19.05]
.250[6.35]
.375[9.53]
.375[9.53]
.093DIA [.76]
.100 [2.54]
.750 [19.05]
.250[6.35]
.405[10.29]
.437 [11.10]
.069[1.75] DIA
TAB (Q.C.)
.154 [3.91] DIA
QC SOLDER LUG
30 AMP
UPTURN LUG
BUS
#8-32 30 AMP
#10-32 50 AMP
BACK CONNECT
M6 STUD
50 AMP
PUSH-IN STUD
50 AMP
#8-32 30 AMP
#10-32 50 AMP
M5 50 AMP
#8-32 30 AMP
#10-32 30 AMP
M5 30 AMP
30 AMP
M4 30 AMP
M4 30 AMP
AUXILIARY SWITCH TERMINAL DETAIL
TABLE A
+.002
-.000
[+.05]
[-.00]
.110 [2.80]
.110 [2.80]
TIGHTENING TORQUE
.161 DIA [Ø 4.10]
.051 DIA[Ø1.29]
SPECIFICATIONS
THREAD SIZE
TORQUE
7-9 IN-LBS
#6-32 & M3 MOUNTING
HARDWARE
#8-32 & M4 THREAD
TERMINAL SCREW
.087 [2.20]
.287 [7.29]
[0.8-1.0 NM]
PUSH-IN STUD
MATING HOLE
.126 [3.20]
.070 DIA [Ø1.80]
12-15 IN-LBS
[1.4-1.7 NM]
15-20 IN-LBS
[1.7-2.3 NM]
#10-32 & M5 THREAD
TERMINAL SCREW
TAB (Q.C.)
SOLDER TYPE
1.313 [33.35]
.520 [13.21]
2.230 [56.64] TYP
TABLE B
LINE
DEPTH
TERMINAL DESCRIPTION
BEHIND PANEL
2.090 [53.09]
2.122 [53.90]
2.612 [66.35]
LINE
TAB (Q.C.)
MAIN
SCREW TYPE
2.000 [50.80]
LOAD
SHUNT, RELAY TAB (Q.C.)
&
SCREW #8-32
W/UPTURNED LUGS
2.644 [67.16]
DUAL COIL
LOAD
TAB (Q.C.) .110 x .020
SOLDER TYPE
2.537 [64.44]
2.348 [59.64]
AUX. SWITCH*
*AVAILABLE ON SERIES TRIP AND SWITCH ONLY CIRCUITS.
WHEN CALLED FOR ON MULTI-POLE UNITS, ONLY ONE AUX.
SWITCH IS NORMALLY SUPPLIED, AS SHOWN IN MULTI-POLE
IDENTIFICATION SCHEME.
.875 [22.23] REF
BARRIER FOR
UL-489 MULTI-POLE
BREAKERS
BARRIER FOR
UL-RECOGNIZED MULTI-POLE
BREAKERS
SEE TABLE-B
DEPTH BEHIND PANEL
.393 [9.96] REF
ON
I
LINE
(NETZ)
MID
TRIP
1.560 [39.62] TYP
30°
2 PLCS
1.936[49.17]
1.350 [34.29]
OFF
O
1.560 [39.62]
TYP
LOAD
(LAST)
.032 [.81]
TYP
PUSH-IN
STUD
SCREW TERMINAL
WITH 30° BEND
M6 STUD
.220 [5.59] TYP
1.250 [31.75]
BACK CONNECT
SCREW TERMINAL
BACK CONNECT
SCREW TERMINAL
WITH RETAINER
Notes:
1
2
All dimensions are in inches [millimeters].
Tolerance ±.020 [.51] unless otherwise specified.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
11
B-Series Circuit Breaker - Handle - Dimensional Specifications
Dimensional Specifications: in. [mm]
Notes:
1
2
All dimensions are in inches [millimeters].
Tolerance ± 0.20 [.51] unless otherwise specified.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
12
B-Series Circuit Breaker - Handle – Front Panel Snap-in Mounting Style 5 – Dimensional Specifications
Dimensional Specifications: in. [mm]
Notes:
1
2
3
All dimensions are in inches [millimeters].
Recommended panel thickness: .040 [1.02] to .100 [2.54].
Tolerance ±.020 [.51] unless otherwise specified.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
13
B-Series Circuit Breaker - Handle – Front Panel Snap-In Mounting Style 7 – Dimensional Specifications
Dimensional Specifications: in. [mm]
Notes:
1
2
3
All dimensions are in inches [millimeters].
Recommended panel thickness: .040 [1.02] to .100 [2.54].
Tolerance ±.020 [.51] unless otherwise specified.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
14
B-Series Circuit Breaker - Rocker UL489 Listed – Ordering Scheme
B F 1 B 0 24 630 2 3 A K G
8
9
10
Mounting/
Barriers
11
12
1
2
3
4
5
6
7
Terminal
Actuator
Color
Max. Appl. Agency
Rating Approval
Series
Actuator
Poles
Circuit
Aux/Alarm
Switch
Frequency
& Delay
Current Rating
5
1 SERIES
8 TERMINAL
6
1
2
3
4
5
6
Push-On 0.250 Tab (Q.C.)
Screw 8-32 with upturned lugs
Screw 8-32 (Bus Type)
Screw 10-32 with upturned lugs
Screw 10-32 (Bus Type)
Screw 8-32 with upturned lugs
& 30° bend
Screw 8-32 (Bus Type)
& 30° bend
Screw 10-32 with upturned lugs
& 30° bend
Screw 10-32 (Bus Type)
& 30° bend
B
C
F
Screw M5 with upturned lugs
Screw M4 with upturned lugs
Screw M5 with upturned lugs
& 30° bend
B
2 ACTUATOR
Two Color Visi-Rocker
G
H
J
K
N
Y
Screw M5 (Bus Type) & 30° bend
Screw M5 (Bus Type)
Single color
C
D
F
Indicate ON, vertical legend
J
Vertical legend
Screw M5 Back Connect
Screw 10-32 Back Connect
Screw M4 Back Connect
Screw 8-32 Back Connect
Indicate ON, horizontal legend
Indicate OFF, vertical legend
Indicate OFF, horizontal legend
K
Horizontal legend
7
8
9
G
9 ACTUATOR COLOR & LEGEND
Actuator or
Marking:
Marking Color
7
7
Visi-Color
ON-OFF
Dual
Single Color Visi-Rocker
White
Black
Red
B
D
G
J
1
2
3
4
5
6
7
8
Black
White
White
White
White
Black
Black
Black
White
n/a
Red
Green
Blue
Green
Blue
L
Yellow
Gray
Orange
N
Q
S
Yellow
Gray
Orange
10 MOUNTING / BARRIERS
1,2
3 POLES
One
9
MOUNTING STYLE
BARRIERS
3
1
2
Two
3
Three
Threaded Insert, 2 per pole
6-32 x 0.195 inches (multi-pole units only)
ISO M3 x 5mm
A
B
yes
yes
4 CIRCUIT
Series Trip (Current)
ROCKERGUARD BEZEL
Threaded Insert, 2 per pole
6-32 X 0.225 inches (multi-pole units only)
ISO M3 x 6.5mm
B
C
D
yes
yes
4
5 AUXILIARY / ALARM SWITCH
0
1
2
3
without Aux Switch
7
S.P.S.T., 0.110 Q.C. Term.
(Gold Contacts)
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
S.P.D.T., 0.093 Q.C. Term.
S.P.D.T., 0.110 Q.C. Term.
S.P.D.T., 0.110 Solder Lug
8
9
11 MAXIMUM APPLICATION RATING
8
C
K
120/240 VAC
120 VAC
6 FREQUENCY & DELAY
21
22
24
26
AC Ultra Short
AC Short
42
44
46
AC, Short, High-inrush
AC, Medium, High-inrush
AC, Long, High-inrush
12 AGENCY APPROVAL
G
3
UL489 Listed
UL489 Listed, TUV Certified
AC Medium
AC Long
Notes:
1
Multi-pole breakers have all breakers identical except when specifying Auxiliary switch
and/or mixed poles, and have one rocker per breaker.
All poles must be same polarity.
7 CURRENT RATING (AMPERES)
CODE AMPERES
2
3
4
5
6
3 pole units available only when 1 of 3 poles is neutral.
On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole.
Screw Terminals are recommended on ratings greater than 20 amps.
Terminal Code 1 (Push-On) available up to 30 amps, but are not recommended over
20 amps.
020 0.020
025 0.025
030 0.030
035 0.035
040 0.040
045 0.045
050 0.050
055 0.055
060 0.060
065 0.065
070 0.070
075 0.075
080 0.080
085 0.085
090 0.090
095 0.095
210 0.100
215 0.150
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
295 0.950
410 1.000
512 1.250
415 1.500
517 1.750
420 2.000
522 2.250
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611 11.000
711 11.500
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
7
8
9
Dual legend = ON-OFF/I-O
Voltage Rating available with 2 and 3-pole breakers only.
Barriers supplied on multi-pole units only.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
15
B-Series Circuit Breaker - Rocker UL489 Listed – Dimensional Specifications
Dimensional Specifications: in. [mm]
Notes:
1
Dimensions apply to all variations shown. Notice that circuit breaker line & load
terminal orientation on indicate “OFF” is opposite of indicate “ON”.
For pole orientation with horizontal legend, rotate front view clockwise 90°.
All dimensions are in inches [millimeters].
2
3
4
Tolerance ±.020 [.51] unless otherwise specified.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
16
B-Series Circuit Breaker - Flat Rocker UL489 Listed – Ordering Scheme
B 1 1 B 0 24 630 2 3 A K G
8
9
10
Mounting/
Barriers
11
12
1
2
3
4
5
6
7
Terminal
Actuator
Color
Max. Appl. Agency
Rating Approval
Series
Actuator
Poles
Circuit
Aux/Alarm
Switch
Frequency
& Delay
Current Rating
6
1 SERIES
8 TERMINAL
7
B
1
2
3
4
5
6
Push-On 0.250 Tab (Q.C.)
Screw 8-32 with upturned lugs
Screw 8-32 (Bus Type)
Screw 10-32 with upturned lugs
Screw 10-32 (Bus Type)
Screw 8-32 with upturned lugs
& 30° bend
Screw 8-32 (Bus Type)
& 30° bend
Screw 10-32 with upturned lugs
& 30° bend
Screw 10-32 (Bus Type)
& 30° bend
B
C
F
Screw M5 with upturned lugs
Screw M4 with upturned lugs
Screw M5 with upturned lugs
& 30° bend
1
2 ACTUATOR
Two Color Visi-Rocker
G
H
J
K
N
Y
Screw M5 (Bus Type) & 30° bend
Screw M5 (Bus Type)
Push-To-Reset, Visi-Rocker
1
2
Indicate OFF, vertical legend
Indicate OFF, horizontal legend
5
6
Indicate OFF, vertical legend
Indicate OFF, horizontal legend
Screw M5 Back Connect
Screw 10-32 Back Connect
Screw M4 Back Connect
Screw 8-32 Back Connect
7
8
9
Single color
Push-To-Reset , Single color
3
4
Vertical legend
Horizontal legend
7
8
Vertical legend
Horizontal legend
9 ACTUATOR COLOR & LEGEND
Actuator or
Marking:
Marking Color
8
8
Visi-Color
ON-OFF
Dual
Single Color Visi-Rocker
White
Black
Red
B
D
G
J
1
2
3
4
5
6
7
8
Black
White
White
White
White
Black
Black
Black
White
n/a
Red
Green
Blue
Green
Blue
L
Yellow
Gray
Orange
N
Q
S
Yellow
Gray
Orange
9
10 MOUNTING / BARRIERS
12
2,3
STANDARD ROCKER BEZEL
Threaded Insert, 2 per pole
FLAT ROCKER ACTUATOR
BARRIERS
3 POLES
One
4
1
2
Two
3
Three
A
B
6-32 x 0.195 inches (multi-pole units only)
ISO M3 x 5mm
yes
yes
4 CIRCUIT
Series Trip (Current)
10
B
RECESSED OFF SIDE ROCKER ACTUATOR
6-32 X 0.225 inches (multi-pole units only)
ISO M3 x 6.5mm
PUSH-TO-RESET BEZEL,Threaded Insert, 2 per pole
6-32 x 0.195 inches
ISO M3 x 5mm
E
F
yes
yes
4
5 AUXILIARY / ALARM SWITCH
0
1
2
3
without Aux Switch
7
S.P.S.T., 0.110 Q.C. Term.
(Gold Contacts)
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
C
D
yes
yes
S.P.D.T., 0.093 Q.C. Term.
S.P.D.T., 0.110 Q.C. Term.
S.P.D.T., 0.110 Solder Lug
8
9
11 MAXIMUM APPLICATION RATING
11
C
K
120/240 VAC
120 VAC
6 FREQUENCY & DELAY
21
22
24
26
AC Ultra Short
AC Short
42
44
46
AC, Short, High-inrush
AC, Medium, High-inrush
AC, Long, High-inrush
AC Medium
AC Long
12 AGENCY APPROVAL
G
3
UL489 Listed
UL489 Listed, TUV Certified
7 CURRENT RATING (AMPERES)
Notes:
CODE AMPERES
1
2
Push-To-Reset actuators have OFF portion of rocker shrouded.
020 0.020
025 0.025
030 0.030
035 0.035
040 0.040
045 0.045
050 0.050
055 0.055
060 0.060
065 0.065
070 0.070
075 0.075
080 0.080
085 0.085
090 0.090
095 0.095
210 0.100
215 0.150
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
295 0.950
410 1.000
512 1.250
415 1.500
517 1.750
420 2.000
522 2.250
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611 11.000
711 11.500
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
Multi-pole breakers have all breakers identical except when specifying Auxiliary switch and/or
mixed poles, and have one rocker per breaker.
3
4
5
6
7
All poles must be same polarity.
3 pole units available only when1 of 3 poles is neutral.
On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole.
Screw Terminals are recommended on ratings greater than 20 amps.
Terminal Code 1 (Push-On) available up to 30 amps, but are not recommended over
20 amps.
8
9
Color shown is visi and legend with remainder of rocker black, Dual = ON-OFF/I-O legend.
Legend on Push-to-reset bezel/shroud is white with single color actuator codes 7 & 8.
Legend on Push-To-Reset bezel/shroud matches Visi-Color of rocker with actuator codes
5 & 6.
10 Recessed “off-side” available with actuator codes 1, 2, 3 & 4. Legends on rocker are available
in ink stamping only.
11 Voltage rating available with 2 & 3-pole breakers only.
12 Barriers supplied on multi-pole units only.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
17
B-Series Circuit Breaker - Flat Rocker UL489 Listed – Dimensional Specifications
Dimensional Specifications: in. [mm]
Notes:
1
2
3
All dimensions are in inches [millimeters].
For pole orientation with horizontal legend, rotate front view clockwise 90°.
Tolerance ±.010 [.25] unless otherwise specified.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
18
B-Series Circuit Breaker – PC Terminal Diagrams
PC Terminal Diagrams: in. [mm]
Notes:
1
2
3
All dimensions are in inches [millimeters].
For pole orientation with horizontal legend, rotate front view clockwise 90°.
Tolerance ±.010 [.25] unless otherwise specified.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
19
Sales Representatives, Distributors & Company Profile
Authorized Sales Representatives and Distributors
Click on a region of the map below to find your local representatives and distributors or visit
www.carlingtech.com/findarep.
CANADA
EUROPE
USA
MIDDLE
EAST
MEXICO
AFRICA
ASIA-PACIFIC
OCEANIA
SOUTH
AMERICA
About Carling
Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches
and assemblies, circuit breakers, electronic controls, power distribution units, and multiplexed power
distribution systems. With four ISO registered manufacturing facilities and technical sales offices worldwide,
Carling Technologies Sales, Service and Engineering teams do much more than manufacture electrical
components, they engineer powerful solutions! To learn more about Carling please visit
www.carlingtech.com/company-profile.
To view all of Carling’s environmental, quality, health & safety certifications please visit
www.carlingtech.com/environmental-certifications
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
Worldwide Headquarters
Carling Technologies, Inc.
60 Johnson Avenue, Plainville, CT 06062
Phone: 860.793.9281 Fax: 860.793.9231
@
Email: sales carlingtech.com
@
Northern Region Sales Office: nrsm carlingtech.com
@
Southeast Region Sales Office: sersm carlingtech.com
@
Midwest Region Sales Office: mrsm carlingtech.com
@
West Region Sales Office: wrsm carlingtech.com
@
Latin America Sales Office: larsm carlingtech.com
Asia-Pacific Headquarters
Carling Technologies, Asia-Pacific Ltd.,
Suite 1607, 16/F Tower 2, The Gateway,
Harbour City, 25 Canton Road,
Tsimshatsui, Kowloon, Hong Kong
Phone: Int + 852-2737-2277 Fax: Int + 852-2736-9332
@
Email: sales carlingtech.com.hk
@
Shenzhen, China: shenzhen carlingtech.com
@
Shanghai, China: shanghai carlingtech.com
@
Pune, India: india carlingtech.com
@
Kaohsiung, Taiwan: taiwan carlingtech.com
@
Yokohama, Japan: japan carlingtech.com
|
|
Europe Middle East Africa Headquarters
Carling Technologies LTD
4 Airport Business Park, Exeter Airport,
Clyst Honiton, Exeter, Devon, EX5 2UL, UK
Phone: Int + 44 1392.364422 Fax: Int + 44 1392.364477
@
Email: ltd.sales carlingtech.com
@
Germany: gmbh carlingtech.com
@
France: sas carlingtech.com
www.carlingtech.com
REV_01_2019
相关型号:
©2020 ICPDF网 联系我们和版权申明